FMUSER 12V 2A DC Power Supply Power Adapter for 0.5w/1w/5w/7w FM Transmitter and Encoder

product-info-mod4 FEATURES

  • Price (USD): 13.99
  • Qty (PCS): 1
  • Shipping (USD): 0
  • Total (USD): 13.99
  • Shipping Method Payment: Airmail Shipping
  • Payment: PayPal

12V 2A DC power adapter power supply is now in stock with a warranty, new listing, factory direct sales, the sales price is the ex-factory price. With FCC/UL certification quality assurance, it can be used for 0.5W, 1W, 5W, 7W transmitters, and encoders.

1 * FMUSER 12V2A power supply (white package)

Input Characteristics

1) Input voltage:

* Rated voltage: 100-240 VAC

* Range of variation: 90-264Vac

2) Input frequency:

* Nominal frequency: 50-60 Hz

* Variation frequency: 47-63 Hz

3) Input current

1.0 Arms max at any input voltage and rated output DC load.

4) Starting current:

30 Amps Max. Cold start at 240 VAC input, rated load, and 25 degrees Celsius environment.

5) AC leakage current: 0.25mA max at 240VAC input

Output Specifications

1) Output power: 24.0W (DC12V, 0A Min. Load, 2.0A Max. Load,> 2.5A peak)

2) Combined Load / Cube Regulation:

Voltage DC12V, + -3% line regulation, + -5% load regulation.

3) Ripple and noise:

Ripple and noise as follows, when measured with a maximum bandwidth of 20MHz and parallel 47uF / 0.1uF, crossed, connected at the test point.

Voltage ripple and noise (max) + 12.0 V DC 120mVp-p

4) Turn on delay time: 2 seconds Max. At 115Vac input and output Max. Load

5) Rise time: 40ms Max. At 115 VAC input and output Max. Load.

6) Hold time: 5ms min. At 115 VAC input and output Max. Load.

7) Efficiency: 80% min. at 100 VAC input and output Max. 80% load min. at 240 VAC input and output Max. Load

8) Exceed a maximum of 15%. When turning on or off the power supply.

Protection Requirements

1) Short circuit protection 

2) Over current protection

3) Overvoltage protection

Environmental Requirements

1) Operating temperature: 0 ~ -40 degrees Celsius, full load normal operation

2) Storage temperature: -20 ~ 85 degrees Celsius.

3) Relative humidity: 5% (0 degrees Celsius) ~ 90% (degrees Celsius), 72 hours, full load normal work.

4) Vibration:

* Operation: IEC721-3-3 3 m3

5-9 Hz, A = 1.5 mm

* Transport: IEC 721-3-2 2 m2

9-200 Hz, acceleration = 5 m / s2

200-500 Hz, acceleration = 15 m / s2

* Axles, 10 cycles per axis:

There can be no damage during testing. The product should restore its original situation after power off / on.

* Lowering: 1 corner, 3 edges, and 6 surfaces.

Certificates: UL. FCC

Packing size: 145 * 72 * 32mm (L * W * H)

Input connector: 2 * 0.5m SRF8

DC cable: AWM2464 22AWG * 2C, VW1, 80 degrees Celsius, FT1, 300 B, with word on cord, length: 0.5m. Without magnetic ring, DC plug 5.5 * 2.1 * 10mm, in + / out-

INQUIRY

vcode

CONTACT US

contact-email
contact-logo

FMUSER INTERNATIONAL GROUP LIMITED.

We are always providing our customers with reliable products and considerate services.

vcode

If you would like to keep touch with us directly, please go to contact us

  • Home

    Home

  • Tel

    Tel

  • Email

    Email

  • Contact

    Contact